Binder currently may service an incoming oneway transaction whenever
an outbound oneway call is made (if there is already a pending
incoming oneway call waiting). The unexpected nested method call
blocks forever on a recursive mutex acquire because healthd is single-
threaded. The binder behavior is considered a bug and may change in
the future. For now, work around this in healthd.
Make a local copy of the listeners list, then drop the lock and
perform the outbound calls on the local copy of the list.
Bug: 38201220
Test: Marlin with modified client calling scheduleUpdate() repeatedly
Change-Id: If35c2847556245921e2aff808ff747bb60356811
scheduleUpdate forces a healthd battery update,
which will notify all listeners.
Test: Manual (strace -p $healthd_pid)
Bug: 32645990
Change-Id: I8b19f79b633ca8988f0e3dd5be14757f6421ddcb
This method is still used by prebuilts, but making it private to start
the process of removing it from everywhere.
Test: pass
Bug: 35363681
Change-Id: I4d53f68d10c9abcca32023c4d930e99912afa697
ev_init() and ev_iterate_available_keys() now take std::function
callback functions.
Test: mmma system/core/healthd
Change-Id: I8231b57ba816fcba8f698dd7145724021e235664
Fixed a bug in makefile that was keeping CHARGER_ENABLE_SUSPEND from
getting properly set, so healthd was not trying to put kernel into
suspend.
Bug: 32162033
Change-Id: If054d7996fa5734285cbcd7d497492570076c141
Devices can now override DEFAULT_PERIODIC_CHORES_INTERVAL_FAST
and DEFAULT_PERIODIC_CHORES_INTERVAL_SLOW by defining a value for
BOARD_PERIODIC_CHORES_INTERVAL_FAST and/or BOARD_PERIODIC_CHORES_INTERVAL_SLOW
in the device's BoardConfig.mk file.
Bug: 32162033
Change-Id: I956fd4760893ae6c2eb3a3af586353d4d66daf25
The binder fd doesn't need to use EPOLLWAKEUP and shouldn't; if it does,
it will prevent suspend unnecessarily.
bug 32180327
Change-Id: I292f1ada0c698290f6bd5518b237867ed69ec391
Allow the charging animation to be customized with a configuration file
and custom assets.
- Add a parser to parse a custom configuration file.
- Add support for showing a clock and the battery percentage.
- Expand feature that conditionally shows animation frames using min_level
and level_only to min_level and max_level
BUG: 29547343
Change-Id: Ia33f4bb37dc7d4c7fa6507a63481e93bf0bf9738
* Use const reference type for parameters to avoid unnecessary copy.
Bug: 30407689
Change-Id: I926ea7b6e9e020a228c812b7e23087a2b7ed9809
Test: build with WITH_TIDY=1
In readFromFile() when a newline is not found in the data, we reset
the initial character of the buffer to \0, but leave the count as is
(something >0 in this case).
Later in getBooleanField() we could erroneously treat a response as
"true" because count would be >0 and the initial value of buf would
be != '0' (set to \0 in this case).
To fixup error paths such as this, we can simplify readFromFile
by using android::base functions: ReadFromFileString() and Trim().
NOTES:
- Converted char * buffers used with readFromFile to std::string
- Removed unused variable btech from BatteryMonitor::update
Testing Done:
- Build healthd and recovery for angler device
- Confirm that known values are being read correctly from kernel
sysfs.
Change-Id: I238bbff097543767f352aa084bf0acbc1324baca
Signed-off-by: Michael Scott <michael.scott@linaro.org>
setting fake properties.
healthd used to check for registered charger drivers to determine if the
device is an always-plugged device with no battery. This patch changes
it to check for battery instead.
Change-Id: Ie4ff5d3f21dc1a83a780a41eb0c929f66b86d631
Signed-off-by: Ruchi Kandoi <kandoiruchi@google.com>
(cherry picked from commit fabd490f58)
When creating static libs with healthd logic, explicitly
reference libbinder to pick up its header include paths.
Bug: 27804373
Test: healthd libs compile when libbinder's header include
paths change.
Change-Id: I1014eb0b73d06815c42a527c4ea7e63c35ca3530
setting fake properties.
healthd used to check for registered charger drivers to determine if the
device is an always-plugged device with no battery. This patch changes
it to check for battery instead.
Change-Id: Ie4ff5d3f21dc1a83a780a41eb0c929f66b86d631
Signed-off-by: Ruchi Kandoi <kandoiruchi@google.com>
With Type-C PD, VBUS can no longer be assumed to
to be at 5V. Read the "voltage_max" field from the
power_supply class node and export it through
BatteryProperties service.
Bug: 25229483
Change-Id: I04e32d9783a21bab375f1724758a9eeace2a047c
recovery needs to know whether the battery is charged.
Bug: 26879394
Change-Id: Ie2a1d06e81878efa3ff432c2015d409a625e473e
(cherry picked from commit aedf6038dc)