* Use const reference type for parameters to avoid unnecessary copy.
Bug: 30407689
Change-Id: I926ea7b6e9e020a228c812b7e23087a2b7ed9809
Test: build with WITH_TIDY=1
In readFromFile() when a newline is not found in the data, we reset
the initial character of the buffer to \0, but leave the count as is
(something >0 in this case).
Later in getBooleanField() we could erroneously treat a response as
"true" because count would be >0 and the initial value of buf would
be != '0' (set to \0 in this case).
To fixup error paths such as this, we can simplify readFromFile
by using android::base functions: ReadFromFileString() and Trim().
NOTES:
- Converted char * buffers used with readFromFile to std::string
- Removed unused variable btech from BatteryMonitor::update
Testing Done:
- Build healthd and recovery for angler device
- Confirm that known values are being read correctly from kernel
sysfs.
Change-Id: I238bbff097543767f352aa084bf0acbc1324baca
Signed-off-by: Michael Scott <michael.scott@linaro.org>
When creating static libs with healthd logic, explicitly
reference libbinder to pick up its header include paths.
Bug: 27804373
Test: healthd libs compile when libbinder's header include
paths change.
Change-Id: I1014eb0b73d06815c42a527c4ea7e63c35ca3530
setting fake properties.
healthd used to check for registered charger drivers to determine if the
device is an always-plugged device with no battery. This patch changes
it to check for battery instead.
Change-Id: Ie4ff5d3f21dc1a83a780a41eb0c929f66b86d631
Signed-off-by: Ruchi Kandoi <kandoiruchi@google.com>
With Type-C PD, VBUS can no longer be assumed to
to be at 5V. Read the "voltage_max" field from the
power_supply class node and export it through
BatteryProperties service.
Bug: 25229483
Change-Id: I04e32d9783a21bab375f1724758a9eeace2a047c
recovery needs to know whether the battery is charged.
Bug: 26879394
Change-Id: Ie2a1d06e81878efa3ff432c2015d409a625e473e
(cherry picked from commit aedf6038dc)
Boards can opt to have charger mode be passive, with no screen UI or key
processing, the same as for recovery mode, via BOARD_CHARGER_NO_UI. The
minui and associated libs and charging image files are not built into the
executable in this case.
Always select charger No UI operation for Brillo devices.
Bug: 27170356
Change-Id: Ibe71498743353b01ce5b6521e42ed94d75547547
and print a warning message containing the type
when the battery monitor fails to recognize a power supply.
Change-Id: I02ebd89736f7444f8bf7f28550afeec82d57e107
Call addService using a reference to a strong pointer to the service object,
such that the proper IBinder object is ref counted, instead of passing the
object's this pointer.
Bug: None
Change-Id: I72cac08c835a17b8cc263b2dc34864420b7a2841
Use 1972 as a right delineation. Otherwise use half way point
between the monotonic and realtime. Treat correction factor as
unsigned, ensure that any wrapping to a negative value is
dropped or set to EPOCH. Acknowledge that we can get a more
accurate time track by acquiring the time rather than relying on
healthd timestamp.
Bug: 26331432
Change-Id: I09075fca58676a30cf7d87baf2d4b0f53795abaa
CL in [1] changes the minui API of res_create_multi_display_surface()
(bootable/recovery/minui/minui.h). Track the change accordingly.
[1] commit b723f4f38f53a38502abb1a63165ac0749bc9cd9
Change-Id: If9684019105ff91d5ade5b69e88849af766c2a19
See the new types added here :
https://chromium-review.googlesource.com/304660
Add support for these.
Signed-off-by: Benson Leung <bleung@google.com>
Change-Id: I12c51e0611692a763a7f1cda57c77ad83d7aa7ea
With Type-C PD, VBUS can no longer be assumed to
to be at 5V. Read the "voltage_max" field from the
power_supply class node and export it through
BatteryProperties service.
Bug: 25229483
Change-Id: I04e32d9783a21bab375f1724758a9eeace2a047c